Hydronic Water Manifolds with Flow Meter for Floor Heating Manifold System

Product Details
Customization: Available
Certification: ISO9001
Heating Type: Water Heating Systems
Still deciding? Get samples of US$ 0/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Fast Delivery
The supplier can deliver the goods within 30 days
Raw-Materials Traceability
The supplier has traceability identification of raw materials
Environmental Protection
The supplier has relevant environmental protection qualifications, including:
-Environmental impact assessment report
-The company have EIA reply
-The supplier actual founding consistent with EIA acceptance comments
-Pollution discharge permit
-Fixed pollution source pollution discharge registration
to see all verified strength labels (34)
  • Hydronic Water Manifolds with Flow Meter for Floor Heating Manifold System
  • Hydronic Water Manifolds with Flow Meter for Floor Heating Manifold System
  • Hydronic Water Manifolds with Flow Meter for Floor Heating Manifold System
  • Hydronic Water Manifolds with Flow Meter for Floor Heating Manifold System
  • Hydronic Water Manifolds with Flow Meter for Floor Heating Manifold System
  • Hydronic Water Manifolds with Flow Meter for Floor Heating Manifold System
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Company Profile
  • Packaging & Shipping
  • WHY CHOOSE US
  • FAQ
Overview

Basic Info.

Transport Package
Carton
Specification
1"
Trademark
Ritable
Origin
China
HS Code
8481804090
Production Capacity
50000000/Year

Product Description

Product Description

Hydronic Water Manifolds with Flow Meter for Floor Heating Manifold System
Hydronic Water Manifolds with Flow Meter for Floor Heating Manifold System
Hydronic Water Manifolds with Flow Meter for Floor Heating Manifold System

The manifold is a device used to connect the main heating water supply pipe and the return pipe in the floor heating system. The water separator is a water distribution device used to connect the water supply pipes of various heating pipes in the water system. The water collector is a water collecting device used to connect the return pipes of various heating pipes in the water system.
 

The detailed information:
 

1 Power:  230V +/- 10%
2 Adjusting range, flow temperature: 20-60ºC
3 Accuracy of temperature control:  +/-1ºC
4 Maximum operating temperature: 90ºC 
5 Minimum operating temperature: 20ºC
6 Maximum operating pressure: 10MPa
7 Material of main components: Brass  
8 External dimensions: 310x220mm 
9 Manifold rails  center - center : 200mm
10 Connection dimensions: 1" Male (swivel nut) or 1" Female
11 Scheme of the mixing module (working): Thermostatic blending

Detailed Photos

Hydronic Water Manifolds with Flow Meter for Floor Heating Manifold System
Features:

1. The sub-catchment is a device used to connect various heating water pipes for water supply and collection in the heating system. According to different usage requirements, 2-8 sub-catchments of different sizes can be provided
2. Use high-quality environmentally friendly brass, long durability
3. Live connection type water outlet for easy pipe cleaning
4. The main body and the branch seam are tightly connected to prevent leakage
5. The water supply pipeline has a protective cap, and the return pipeline has a balance valve that can manually adjust the flow.


 
Applications:
Radiant floor heating systems:
Reinforced Concrete Slabs (4 - 6") - garages, warehouse, storage and manufacturing facilities);
Non-Reinforced Gypsym or Thermal Mass Slabs / Thin Slabs (up to 1-1/4") - radiant heating floors in residential construction;
Staple-up Systems: stapled to the bottom of the subfloor between joists - with or without heat transfer plates;
"Sandwich" Systems: installed between the subfloor and finished floor - with or without heat transfer plates.
Snow and ice melting systems:
Snow melting systems for driveways, walkways; roof deicing applications.

 
Hydronic Water Manifolds with Flow Meter for Floor Heating Manifold System

Hydronic Water Manifolds with Flow Meter for Floor Heating Manifold System

Company Profile

Hydronic Water Manifolds with Flow Meter for Floor Heating Manifold System
 

Packaging & Shipping

Hydronic Water Manifolds with Flow Meter for Floor Heating Manifold System

WHY CHOOSE US

Hydronic Water Manifolds with Flow Meter for Floor Heating Manifold System

FAQ

Q1: Can I have a sample before placing the order?

A: Yes, we would like to provide you samples for testing and checking before quantity purchasing

Q2: What is your MOQ order?

A: Usually 3000 for ordinary products, and 5000pcs for product needs new mold.

Q3.How to proceed an order for your products?

A: Firstly, pls let us know your requirments and application

    Seconly, we provide quotation accordingly or suggestion

    Thirdly, samples confirmation

    Forth, place order and deposit and production arrangement.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier